Ultrafiltration is a technology that simultaneously concentrates and separates large molecules or colloidal substances. Driven by the pressure difference, when the liquid flows on the surface of the ultrafiltration membrane, large molecules or colloidal substances are trapped, and small molecules and pure water pass through the membrane. The pore size of the ultrafiltration membrane for water treatment is roughly between 0.01-0.1um. According to different material, ultrafiltration membrane generally are divided into PVC Ultrafiltration Membrane, PAN Ultrafiltration Membrane, PVDF Ultrafiltration Membrane, PS Ultrafiltration Membrane.


Before starting the ultrafiltration system, you should first check that the following requirements meet the operating standards: 1. The ultrafiltration pretreatment system is operating normally, and the ultrafiltration water intake comply with the design requirement; 2. The drainage system is ready; 3. PLC program has been input as required; 4. The circuit system check has been completed and the pump is operating normally; 5. The pipe system is connected and cleaned.


After completing the pre-startup inspection of ultrafiltration system, start the ultrafiltration system according to the following steps: 1. Start the raw water pump; 2. Filling and flushing of the ultrafiltration system; 3. Set and adjust the inlet water pressure and the system’s water production; 4. Start the backwash pump, set and adjust the backwash pressure; 5. Set and adjust the intake pressure; 6. Set and adjust chain alarm points; 7. Set the backwash time interval; 8. Set the interval of air scrubbing time; 9. Set backwashing sequence of parallel device. The following form are for your reference:


Ultrafiltration System Interlock and Alarm
1Set PointInlet pressure of ultrafiltration system is too high
Set ValueNormal inlet pressure + 1.0bar
Chain ContentActivate the alarm and the system goes to the state to be started
Chain DelayThe alarm is activated after a delay of 5 seconds, and the system switches to the standby state in 10 seconds
2Set PointOutlet pressure of ultrafiltration system is too high
Set ValueNormal outlet pressure + 0.5bar
Chain ContentActivate the alarm and the system goes to the state to be started
Chain DelayThe alarm is activated after a delay of 5 seconds, and the system switches to the standby state in 10 seconds
3Set PointSodium hypochlorite dosing tank level is too low
Set ValueThe minimum distance from the bottom of the container is 7cm
Chain ContentActivate the alarm, shut down the metering pump, the operator adds sodium hypochlorite solution to the dosing box
Chain PeriodThe ultrafiltration system is in working condition


In order to prolong the service life of the ultrafiltration system, daily maintenance is essential, such as checking the temperature of the centrifugal pump and motor, and whether the water pump, valves, pipes and components of the ultrafiltration system are water leaking or air leaking. The following system failure analysis table are for your review:


PhenomenonPossible ReasonCorrective Measures
Ultrafiltration membrane pressure difference is too highUltrafiltration membrane module is contaminatedIdentify the cause of pollution, take corresponding cleaning methods, adjust cleaning parameters
Water flow is too highAdjust the flow according to the requirements in the operation guide
Inlet water temperature is too lowIncrease the inlet water temperature
Low water production flowUltrafiltration membrane module is contaminatedIdentify the cause of pollution, take corresponding cleaning methods, adjust cleaning parameters
Incorrect valve opening settingCheck and ensure that all valves that should be opened are in the open state, and adjust the valve opening
Flow meter problemCheck the flow meter to ensure normal working status
Water supply pressure is too lowCheck the water inlet pressure and adjust the pressure to meet the operating standard
Inlet water temperature is too lowIncrease the inlet water temperature
Poor water qualityInlet water quality exceeds the allowable rangeCheck incoming water quality, mainly turbidity, COD
The membrane module is damagedFind the cause of damage, repair or replace the membrane module
The system cannot run in the automatic stateWater supply pump does not startEliminate the possibility of wiring error, restart the pump in the manual state, and switch to automatic control after normal operation
Inlet pressure is too highCheck the water pump and pressure switch settings
High product water back pressureThe product water outlet valve is not opened, the subsequent system is not started in time, and the pressure switch setting problem
PLC program errorCheck the program