NFC Series Nylon Membrane Pleated Filter Cartridges are made of Hydrophilic Nylon 6 membrane with absolutely rated and good support materials. Nylon membrane pleated filters have superior filtration efficiency, providing the cleanest process fluids in a variety of fine filtration applications.
Nylon 6 membranes enquire no pre-wetting and are easy to install. With wide chemical compatibility and thermostability, nylon pleated cartridges are ideal options for satisfying various requirements in chemical filtration industry, such as final filtration. Nylon membrane filters are without adhesives, binders or surfactants when used in the manufacturing process. What’s more importantly, they are 100% integrity tested to ensure good performance with high flow rate.
Filter Media | Nylon |
Length | 5", 9.75", 9.8", 10", 20", 30", 40" |
Outside Diameter | 2.75"(70mm) |
Filtration Rating | 0.1μm, 0.22μm, 0.45μm, 0.65μm, 1μm |
Core | Polypropylene |
Filter Support | Polypropylene |
Gasket/O-ring | Silicone, EPDM, Viton, NBR, Teflon encapsulated Viton |
End Cap/Cage | Polypropylene |
End Cap Type | DOE, 222/Flat, 222/Fin(Code 3), 226/Flat, 226/Fin(Code 7), 215/Flat, 215/Fin |
● Nylon membrane filters are free of additives, binders and lubricants
● Nylon membrane pleated filter cartridges use materials complying with FDA standard
● Nylon pleated cartridges have high temperature-resistance, acid and alkaline resisting ability
● Wide chemical compatibility makes nylon pleated filters are ideal for chemical industries requiring high purity
● High-surface-area design provides excellent flow capacity and long service life with consistence of good performance
Inks | Solvents | Cosmetics |
Chemicals | Food & Beverage | RO/DI Process |
Semiconductor | Medicine Filtration | Petrochemical industry |
Operation Data for Nylon Membrane Pleated Filter Cartridges
Maximum Operating Temperature | 110℃(230℉) |
Max. Differential Pressure | 4.8 bar at 50℃ (70 psi at 122℉) |
3.4 bar at 80℃ (50 psi at 176℉) | |
1.8 bar at 110℃(20 psi at 230℉) | |
Maximum reverse pressure | 40 psid @ 70°F (2.8 bar @ 21°C) |
Recommended Change Out Differential Pressure | 2.4 bar (35 psid) |
Sterilization Temperature Time | 121˚C (250˚F) for 30 minutes at 1.0 bar (14 psi), multiple cycles |
Pressure Drop Rate for 10" Nylon Membrane Pleated Filter Cartridges
End Caps of Nylon Membrane Pleated Filter Cartridges
NFC | Length | Micron Rating | End Cap | Gasket/O-ring |
NFC Series Nylon Membrane Pleated Filter Cartridges | 5 = 5" | 0.1 = 0.1μm | A = Double Open End (DOE) | S = Silicone |
9.75 = 9.75" | 0.22 = 0.22μm | B = 222/Flat(SOE) | E = EPDM | |
9.8 = 9.8" | 0.45 = 0.45μm | C = 222/Fin(SOE) | N = NBR | |
10 = 10" | 0.65 = 0.65μm | D = 226//Flat(SOE) | V = Viton | |
20 = 20" | F = 226/Fin(SOE) | |||
30 = 30" | 1 = 1μm | G = 215/Flat(SOE) | T = Teflon Encapsulated Viton | |
40 =40" | H = 215/Fin(SOE) |
For Example:
NFC-10-1-A-E
NFC Series Nylon Membrane Pleated Filter Cartridges - 10" - 1μm - DOE - EPDM
Customized Sizes of Nylon Membrane Pleated Filters can be accepted